254 research outputs found

    Admissibility condition for exceptional Laguerre polynomials

    Get PDF
    We prove a necessary and sufficient condition for the integrability of the weight associated to the exceptional Laguerre polynomials. This condition is very much related to the fact that the associated second order differential operator has no singularities in (0,+)(0,+\infty).Comment: 12 page

    Assessment of a Universal Reconfiguration-less Control Approach in Open-Phase Fault Operation for Multiphase Drives

    Get PDF
    Multiphase drives have been important in particular industry applications where reliability is a desired goal. The main reason for this is their inherent fault tolerance. Di erent nonlinear controllers that do not include modulation stages, like direct torque control (DTC) or model-based predictive control (MPC), have been used in recent times to govern these complex systems, including mandatory control reconfiguration to guarantee the fault tolerance characteristic. A new reconfiguration-less approach based on virtual voltage vectors (VVs) was recently proposed for MPC, providing a natural healthy and faulty closed-loop regulation of a particular asymmetrical six-phase drive. This work validates the interest in the reconfiguration-less approach for direct controllers and multiphase drives

    Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance

    Get PDF
    Multiphase machines provide continuous operation of the drive with no additional hardware in the event of one or more open-phase faults. This faulttolerant capability is highly appreciated by industry for security and economic reasons. However, the steadystate post-fault operation has only been feasible in previous works after the fault localization and control reconfiguration. Even though this is done at the software stage, the obligation to identify the faulty phases and store the modifications for every fault scenario adds further complexity. This work reveals that this software reconfiguration can be avoided if the field-oriented control (FOC) strategy is designed to satisfactorily handle pre- and post-fault situations. Experimental results confirm the capability to obtain suitable postfault operation without fault localization and control reconfiguration, thus achieving a passive/natural fault tolerance.Ministerio de Ciencia, Innovación y Universidades RTI2018-096151-B-I0

    Impact of post-fault flux adaptation on six-phase induction motor drives with parallel converters

    Get PDF
    The redundancy of multiphase drives provides an inherent fault-tolerant capability that is appreciated in applications with a complicated corrective maintenance or safety-critical requirements. Fault restrictions however force the system to be reconfigured to operate in a smooth and efficient manner. Previous works have been focused on the optimization of current waveforms to generate an undisturbed operation but still maintaining the pre-fault rated flux settings. This work shows that efficient controllers can improve the post-fault performance in six-phase induction machines supplied by parallel- connected converters if offline optimization is used to obtain a variable reference flux. Theoretical and experimental results confirm that the proposed flux adaptation method provides higher torque/power capability, lower degree of imbalance in the current sharing between windings and efficiency improvementMinisterio de Ciencia e Innovación ENE2014-52536-C2-1-R DPI2013- 44278-RJunta de Andalucía P11-TEP-755

    Application of DSP in Power Conversion Systems — A Practical Approach for Multiphase Drives

    Get PDF
    Digital Signal Processing is not a recent research field, but has become a powerful technology to solve engineering problems in the last few decades due to the introduction by Texas Instruments in 1982 of the Digital Signal Processor. Fast digital signal processors have quickly become a cornerstone of high-performance electrical drives, where power electronic conversion systems have heavy online computation burdens and must be controlled using complex control algorithms. In this sense, multiphase drives represent a particularly interesting case of study, where the computational cost highly increases with each extra phase. This technology has been recognized in recent times as an attractive electrical drive due to its usefulness in traction, more-electric aircraft applications and wind power generation systems. However, the complexity of the required control algorithms and signal processing techniques notably increases in relation with conventional three-phase drives. This chapter makes a revision of the necessities of a high-performance multiphase drive from the digital signal processing perspective. One of the most powerful Texas Instruments’ digital signal processor (TMS320F28335) is used, and specific control algorithms, electronic circuits and acquisition processing methods are designed, implemented and analyzed to show its interest in the development of a high-performance multiphase drive

    Bernoulli–Dunkl and Apostol–Euler–Dunkl polynomials with applications to series involving zeros of Bessel functions

    Get PDF
    We introduce Bernoulli–Dunkl and Apostol–Euler–Dunkl polynomials as generalizations of Bernoulli and Apostol–Euler polynomials, where the role of the derivative is now played by the Dunkl operator on the real line. We use them to find the sum of many different series involving the zeros of Bessel functions

    Multiphase Current Imbalance Localization Method Applied to Natural Fault- Tolerant Strategies

    Get PDF
    Multiphase machines are interesting options for high-reliability applications due to their inherent fault tolerance against open-circuit faults (OCFs). Moreover, if the regulation of the x-y currents is realized in open-loop mode using virtual voltage vectors (VVs), the mandatory post-fault control reconfiguration is avoided. The new reconfiguration-less approach was recently defined as a natural/passive fault-tolerant strategy, offering good prospects for industry applications. This work extends the idea to the fault detection (FD) procedure and suggests new settings for the current imbalance localization (CIL) method. The proposal is based on the vector space decomposition (VSD) approach that allows the joint detection of OCFs and stator resistances dissymmetry (RDs). Experimental results in a five-phase induction motor (IM) drive using VVs confirm the viability of the technique

    Fault-tolerant Operation of Six-phase Energy Conversion Systems with Parallel Machine-side Converters

    Get PDF
    The fault tolerance provided by multiphase machines is one of the most attractive features for industry applications where a high degree of reliability is required. Aiming to take advantage of such postfault operating capability, some newly designed full-power energy conversion systems are selecting machines with more than three phases. Although the use of parallel converters is usual in high-power three-phase electrical drives, the fault tolerance of multiphase machines has been mainly considered with single supply from a multiphase converter. This study addresses the fault-tolerant capability of six-phase energy conversion systems supplied with parallel converters, deriving the current references and control strategy that need to be utilized to maximize torque/power production. Experimental results show that it is possible to increase the postfault rating of the system if some degree of imbalance in the current sharing between the two sets of threephase windings is permitted.Ministerio de Ciencia e Innovación ENE2014-52536-C2–1-R DPI2013-44278-RJunta de Andalucía P11-TEP-755

    Model Predictive Control based on Dynamic Voltage Vectors for Six-phase Induction Machines

    Get PDF
    Model predictive control (MPC) has been recently suggested as an interesting alternative for the regulation of multiphase electric drives because it easily exploits the inherent advantages of multiphase machines. However, the standard MPC applies a single switching state during the whole sampling period, inevitably leading to an undesired x y voltage production. Consequently, its performance can be highly degraded when the stator leakage inductance is low. This shortcoming has been, however, mitigated in recent work with the implementation of virtual/synthetic voltage vectors (VVs) in MPC strategies. Their implementation reduces the phase current harmonic distortion since the average x y voltage production becomes null. Nevertheless, VVs have a static nature because they are generally estimated offline, and this implies that the flux/torque regulation is suboptimal. Moreover, these static VVs also present some limitations from the point of view of the dc-link voltage exploitation. Based on these previous limitations, this article proposes the implementation of dynamic virtual voltage vectors (DVVs), where VVs are created online within the MPC strategy. This new concept provides an online optimization of the output voltage production depending on the operating point, resulting in an enhanced flux/torque regulation and a better use of the dc-link voltage. Experimental results have been employed to assess the goodness of the proposed MPC based on DVVs.Ministerio de Ciencia, Innovación y Universidades RTI2018-096151-B-100

    Combined therapies of antithrombotics and antioxidants delay in silico brain tumor progression

    Full text link
    Glioblastoma multiforme, the most frequent type of primary brain tumor, is a rapidly evolving and spatially heterogeneous high-grade astrocytoma that presents areas of necrosis, hypercellularity and microvascular hyperplasia. The aberrant vasculature leads to hypoxic areas and results in an increase of the oxidative stress selecting for more invasive tumor cell phenotypes. In our study we assay in silico different therapeutic approaches which combine antithrombotics, antioxidants and standard radiotherapy. To do so, we have developed a biocomputational model of glioblastoma multiforme that incorporates the spatio-temporal interplay among two glioma cell phenotypes corresponding to oxygenated and hypoxic cells, a necrotic core and the local vasculature whose response evolves with tumor progression. Our numerical simulations predict that suitable combinations of antithrombotics and antioxidants may diminish, in a synergetic way, oxidative stress and the subsequent hypoxic response. This novel therapeutical strategy, with potentially low or no toxicity, might reduce tumor invasion and further sensitize glioblastoma multiforme to conventional radiotherapy or other cytotoxic agents, hopefully increasing median patient overall survival time.Comment: 8 figure
    corecore